Dec 24, 2011 Hi everybody, Question is: how to design a vertical atmospheric tank with an operational temperature of 560°C. The material is SS321H. Someone suggested me to u. API 560 Standard. All posts for API 560 Standard. Looks like there is nothing here yet. Why not start the ball rolling? « » Add post. It's free to post to OilVoice. You'll reach our 30,000 Twitter followers and huge upstream audience. Top Opinion View all Bakken Gas Threatens Crude Production OilVoice Press.
Tomapoingo, that is exactly the method I would use. And I would plainly document the source of my Allowable Stress on the design drawing and on the calc sheet. Thus either document will answer the question of an API-style tank at 560°C Make sure that you pick a Design Temp that the operators will not exceede. This tank will be one of the first ones to be audited when regulators arrive at your plant. It needs to be carefully documented, and always operated within the design limitations that you set.
RE: Molten salt storage tank design: limitation of API 650 code. Thank you doct9960 for your fast support but the design of storage tank is made with API650 which has temperature limitations. In the document you sent to me they proceed with API 650 without explaining its limitation. I think the only solution with the actual status of codes, it is to design with API650 and mention the temperature effect on SS321H based on ASME code like duwe6 is suggesting that is the way involved people want to proceed here in Italy. I wonder whether by proceeding like that the designer could have problems in terms of responsability if something will happen during the operational phase. Thank you BR Vincenzo RE: Molten salt storage tank design: limitation of API 650 code (Mechanical) 21 Dec 11 16:38.
I think the only solution with the actual status of codes, it is to design with API650 and mention the temperature effect on SS321H based on ASME code like duwe6 is suggesting that is the way involved people want to proceed here in Italy.I would also proceed with this methodology and supplement the design with other analyses (fatigue, thermal stress, FEA, etc.). But take note of what the Foreword in API 650 says. If you do not meet the minimum requirements of API 650 or if you exceed limitations, you cannot reference API 650 on nameplates or Manufacturer's certification. The most important thing is what vpl has said.consult with the local jurisdiction.
I wonder whether by proceeding like that the designer could have problems in terms of responsability if something will happen during the operational phase.That is why you will need to get the all the required information from the Owner/User, perform the proper analysis, and consult with your jurisdiction to make sure it does not fail. Most of the time, an equipment fails because of the the Owner/User, i.e.
Specifying incorrect material, operator error, exceeding equipment design limits, or not providing information such as site conditions or pressure/temperature cycles. The US Department of Energy was able to design an API 650 tank that operated at 565°C. This was for the Solar Two project in the Mojave desert. The plant was just operational for almost 3 years.
I believe it was decommissioned because it was not competitive with fossil fuel. More conclusive proof about the tank's design capability could have been achieved if the plant was still operational to this day. RE: Molten salt storage tank design: limitation of API 650 code (Mechanical) 22 Dec 11 17:38. Very good reference, doct9960. Tomapoingo, if you'll look through that reference, the facility in question was designed by Bechtel (which is still around) and the tanks were built by PDM, which was bought out by CBI, which is also still around, and also works internationally. And they reference a couple of technical papers or books on the design of the salt equipment.
So I think the expertise to design and build the tank is out there. The use of API-650 gives you standard details, specific materials, design loads, allowable stresses, etc.
In this case, though, you may need to supplement standard details anyway. You're using materials not covered by the standard, and allowable stresses must come from elsewhere. Design loads could come from API-650 or ASCE 7-05 or equivalent European building codes. So I don't think it's going to make much difference which standard you start with. You could also use ASME B&PV Code or other vessel codes, applied 'to the extent applicable' just as with API-650.
In any case, issues such as corrosion, metallurgy, thermal fatigue and detailing for molten salts are not covered by the standards and would require additional investigation. Secret Files Tunguska Pal Multi5 Wii Mini. One other point is that if this tank is fairly small, say, 4 m diameter x 5 m high, the design issues and concerns are much reduced. If it's a huge tank, then it merits much more consideration.
One other thing is that it might be worthwhile to consult the supplier of the salt in question. If they have previously furnished it, or specifically sell it for this purpose, they may also have recommendations on materials and detailing for storage. RE: Molten salt storage tank design: limitation of API 650 code (Nuclear) 24 Dec 11 22:02. Equally important, if not more than simply 'copying' the details of one standard to a second, very different application simply to be able to say 'We met the design standards of XYZ123' (or API or any other 'standard' is to develop the design to meet the special criteria of the special situation. High temperature. High cycling stresses (expansion, contraction) as it operates. If ignition, then burns and secondary failures when the molten salt hits water, air lines, and oil lines or motors and high voltage lines.
Cooling water? 'Splashing' of molten salt from an elevation above ground? Recovery of the area after the salt solidifies? Corrosion was mentioned above. But crevice cracking?
Weld failure? Startup from 0,0 conditions? You very, very seldom can just copy assumed design solutions and safety margins from one Standard to a different circumstance just to 'meet code' and succeed.
About product and suppliers: Alibaba. Crack Left For Dead 2 Skidrow Game. com offers 95 api 560 standard products. About 40% of these are steel pipes. A wide variety of api 560 standard options are available to you, such as 10#, q195, and 20#. You can also choose from structure pipe, fluid pipe, and boiler pipe. As well as from hot rolled, cold rolled, and erw. And whether api 560 standard is free samples.
There are 95 api 560 standard suppliers, mainly located in Asia. The top supplying country is China (Mainland), which supply 100% of api 560 standard respectively. Api 560 standard products are most popular in Mid East, Southeast Asia, and Eastern Asia. You can ensure product safety by selecting from certified suppliers, including 95 with Other, 52 with ISO9001 certification.